680
FX3G/FX3U/FX3UC Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
27 Data Operation 3 – FNC210 to FNC219
27.3 FNC212 – POP / Shift Last Data Read [FILO Control]
27.3 FNC212 – POP / Shift Last Data Read [FILO Control]
Outline
This instruction reads the last data written by shift write (SFWR) instruction for FILO control.
For SFWR (FNC 38) instruction, refer to Section 11.9.
1. Instruction format
2. Set data
3. Applicable devices
Explanation of function and operation
1. 16-bit operation (POP and POPP)
Data for FILO control
Every time the instruction is executed for the word devices to +n-1, a device “ + Pointer
data ” is read to . (The last data entry written by the shift write (SFWR) instruction for first-in
first-out control is read to .) Specify “n” in the range from “2” to “512”.
Operand Type Description Data Type
Head device number storing first-in data (including pointer data)
16-bit binary
Device number storing last-out data
n
Length of data array
(Add "1" because pointer data is also included.)
2 n 512
Oper-
and
Type
Bit Devices Word Devices Others
System User Digit Specification System User
Special
Unit
Index
Con-
stant
Real
Number
Charac-
ter String
Pointer
XYMTCSD
.b KnX KnY KnM KnS T C D R
U\G
VZModifyKH E "
"P
3 3 3 3333 3 3
3333333 3 333
n 33
Description
Pointer data (amount of data stored)
+1
Data area
(First-in data written by shift write (SFWR) instruction)
+2
+3
...
+n-3
+n-2
+n-1
Mnemonic Operation Condition
16-bit Instruction
7 steps
POP
POPP
Mnemonic Operation Condition
Continuous
Operation
Pulse (Single)
Operation
32-bit Instruction
P
FNC 212
POP
S
D
S
D
FNC212
POPP
S
D
n
Command
input
S
S
S
S
S
S
S
S
S
S
S
D
D