EasyManua.ls Logo

Mitsubishi Electric MELSEC FX3U - 20 Positioning Control - FNC150 to FNC159

Mitsubishi Electric MELSEC FX3U
1000 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
571
FX3G/FX3U/FX3UC Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
20 Positioning Control – FNC150 to FNC159
11
FNC30-FNC39
Rotation and
Shift
12
FNC40-FNC49
Data Operation
13
FNC50-FNC59
High Speed
Processing
14
FMC60-FNC69
Handy
Instruction
15
FNC70-FNC79
External FX I/O
Device
16
FNC80-FNC89
External FX
Device
17
FNC100-FNC109
Data
Transfer 2
18
FNC110-FNC139
Floating Point
19
FNC140-FNC149
Data
Operation 2
20
FNC150-FNC159
Positioning
Control
20. Positioning Control – FNC150 to FNC159
FNC150 to FNC159 provide positioning instructions using the built-in pulse output function of the PLC.
For details, refer to the Positioning Control Edition manual.
Caution on writing during RUN
During RUN, avoid writing while any positioning control instruction (FNC150, FNC151, or FNC156 to
FNC159) is executed (that is, while pulses are output).
If program write is executed during RUN to a circuit block including a target instruction below while pulses are
being output, the PLC executes the operation shown below.
*1. Only available for FX
3U/FX3UC PLC Ver.2.20 or later and FX3G PLC.
FNC No. Mnemonic Symbol Function Reference
150 DSZR DOG Search Zero Return
Section
20.1
151 DVIT Interrupt Positioning
Section
20.2
152 TBL Batch Data Positioning Mode
Section
20.3
153
154
155 ABS Absolute Current Value Read
Section
20.4
156 ZRN Zero Return
Section
20.5
157 PLSV Variable Speed Pulse Output
Section
20.6
158 DRVI Drive to Increment
Section
20.7
159 DRVA Drive to Absolute
Section
20.8
Target instruction
PLC operation when writing excuted during RUN while instruction is
executed
DSZR (FNC150)
Decelerates and stops pulse output.
DVIT (FNC151)
TBL (FNC152) Disables writing during RUN.
ZRN (FNC156) Decelerates and stops pulse output.
PLSV (FNC157)
During operation with
acceleration/deceleration
*1
Decelerates and stops pulse output.
During operation without
acceleration/deceleration
Immediately stops pulse output.
DRVI (FNC158)
DRVA (FNC159)
Decelerates and stops pulse output.
D2DSZR D1S2S1
D2DVIT D1S2S1
nTBL D
D2D1ABS S
DS3ZRN S2S1
PLSV D1 D2S
DRVI D1 D2S2S1
DRVA D1 D2S2S1

Table of Contents

Related product manuals