EasyManua.ls Logo

Mitsubishi Electric MELSEC FX3U - Appendix B-5 Execution Time of Pulse Generation Instruction P in each Applied Instruction

Mitsubishi Electric MELSEC FX3U
1000 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
980
FX3G/FX3U/FX3UC Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
B Instruction Execution Time
B-5 Execution Time of Pulse Generation Instruction P in Each Applied Instruction
Appendix B-5 Execution Time of Pulse Generation Instruction P in Each
Applied Instruction
•FX3U/FX3UC PLCs
•FX
3G PLCs (Standard mode)
Applied instruction Execution time Remarks
MOV instruction (FNC 12)
Execution time at rising edge of input: Execution time in ON status 1.22 µs in MOVP instruction
Non-execution time: Execution time in OFF status
Other applied instructions
Execution time at rising edge of input: Execution time in ON status +
0.45 µs
Non-execution time: Execution time in OFF status + 0.45 µs
Applied instruction Execution time Remarks
MOV instruction (FNC 12)
Execution time at rising edge of input: Execution time in ON status = 4.98 µs
Non-execution time: Execution time in OFF status = 0.8 µs
BCD instruction (FNC 18)
Execution time at rising edge of input: Execution time in ON status = 5.03 µs
Non-execution time: Execution time in OFF status = 0.75 µs
BIN instruction (FNC 19)
Execution time at rising edge of input: Execution time in ON status = 5.03 µs
Non-execution time: Execution time in OFF status = 0.75 µs
ADD instruction (FNC 20)
Execution time at rising edge of input: Execution time in ON status = 6.37 µs
Non-execution time: Execution time in OFF status = 0.75 µs
SUB instruction (FNC 21)
Execution time at rising edge of input: Execution time in ON status = 6.47 µs
Non-execution time: Execution time in OFF status = 0.75 µs
MUL instruction (FNC 22)
Execution time at rising edge of input: Execution time in ON status = 7.07 µs
Non-execution time: Execution time in OFF status = 0.75 µs
DIV instruction (FNC 23)
Execution time at rising edge of input: Execution time in ON status = 7.03 µs
Non-execution time: Execution time in OFF status = 0.75 µs
INC instruction (FNC 24)
Execution time at rising edge of input: Execution time in ON status = 3.48 µs
Non-execution time: Execution time in OFF status = 0.75 µs
DEC instruction (FNC 25)
Execution time at rising edge of input: Execution time in ON status = 3.48 µs
Non-execution time: Execution time in OFF status = 0.75 µs
WAND instruction (FNC 26)
Execution time at rising edge of input: Execution time in ON status = 6.42 µs
Non-execution time: Execution time in OFF status = 0.75 µs
WOR instruction (FNC 27)
Execution time at rising edge of input: Execution time in ON status = 6.42 µs
Non-execution time: Execution time in OFF status = 0.75 µs
WXOR instruction (FNC 28)
Execution time at rising edge of input: Execution time in ON status = 6.42 µs
Non-execution time: Execution time in OFF status = 0.75 µs
Other applied instructions
Execution time at rising edge of input: Execution time in ON status + 0.45 µs
Non-execution time: Execution time in OFF status + 0.45 µs

Table of Contents

Related product manuals