FX3G/FX3U/FX3UC Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
2 Overview (Sequence Program)
2.7 Types and Setting of Parameters
1
Introduction
2
Overview
3
Instruction
List
4
Devices
in Detail
5
Specified the
Device &
Constant
6
Before
Programming
7
Basic
Instruction
8
FNC00-FNC09
Program Flow
9
FNC10-FNC19
Move & Compare
10
FNC20-FNC29
Arith. & Logic
Operation
7 Setting the PLC system (2)
1. Click "PLC system (2)" tab.
2. Only when a latch (battery backed) area for a serial port exists through an extended PLC,
select a channel to be set and put a check mark to "Operate communication setting."
When not performing the communication setting for a serial port, do not put a check mark
to "Operate communication setting."
Set item Contents of setting Setting range
Channel selection Select a channel in which a serial port is set. CH1,CH2
Operate communication
setting
Put a check mark when using the selected serial port in "computer link",
"no-protocol communication" or "inverter communication".
Do not put a check mark when transferring and monitoring sequence
programs in GX Developer or when using the selected serial port in
simple N : N link or parallel link.
Protocol
Set each item in accordance with application.
For details on each item, refer to the Data Communication Edition manual.
Data length
Parity
Stop bit
Transmission speed
Header
Terminator
Control line
H/W type
Control mode
Sum check
Transmission control
procedure
Station number setting
Time out judge time
Channel selection
This example shows a window
in an FX
3U/FX3UC PLC.