706
FX3G/FX3U/FX3UC Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
29 Data Table Operation – FNC250 to FNC269
29.3 FNC258 – ZONE / Zone Control
29.3 FNC258 – ZONE / Zone Control
Outline
Depending on how the input value compares to positive or negative, the output value is controlled by the bias
value specified.
1. Instruction format
2. Set data
3. Applicable devices
Explanation of function and operation
1. 16-bit operation (ZONE and ZONEP)
The bias value specified by or is added to the input value specified by , and output to the
device specified by .
The bias value is added as shown below:
Operand Type Description Data Type
Negative bias value to be added to the input value
16- or 32-bit binary
Positive bias value to be added to the input value
Input value controlled by the zone
Head device number storing the output value controlled by the zone
Oper-
and
Type
Bit Devices Word Devices Others
System User Digit Specification System User
Special
Unit
Index
Con-
stant
Real
Number
Charac-
ter String
Pointer
XYMTCSD
.b KnX KnY KnM KnS T C D R
U\G
VZModifyKH E "
"P
33333333 3 333
33333333 3 333
33333333 3 3
3 3 3 3333 3 3
P
FNC 258
ZONE
D
Mnemonic Operation Condition
16-bit Instruction
9 steps
ZONE
ZONEP
Mnemonic Operation Condition
Continuous
Operation
Pulse (Single)
Operation
32-bit Instruction
17 steps
DZONE
DZONEP
Continuous
Operation
Pulse (Single)
Operation
S
1
S
2
S
3
D
S
1
S
2
S
3
D
S
1
S
2
S
3
D
In the case of “ Input value < 0” ..... Input value + Negative bias value
Output value
In the case of “ Input value = 0” ...........................................................................0
Output value
In the case of “ Input value > 0” ..... Input value + Positive bias value
Output value
FNC258
ZONE
0
Positive bias value
S
1
S
2
D
S
3
S
3
S
3
S
3
S
3
S
3
S
1
S
2
D
D
D
Output
value
Output
value
()
D
Input
value
Input
value
()
S
3
()S
2
Negative bias value
()
S
1
Command