515
FX3G/FX3U/FX3UC Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
18 Floating Point – FNC110 to FNC139
18.4 FNC116 – ESTR / Floating Point to Character String Conversion
11
FNC30-FNC39
Rotation and
Shift
12
FNC40-FNC49
Data Operation
13
FNC50-FNC59
High Speed
Processing
14
FMC60-FNC69
Handy
Instruction
15
FNC70-FNC79
External FX I/O
Device
16
FNC80-FNC89
External FX
Device
17
FNC100-FNC109
Data
Transfer 2
18
FNC110-FNC139
Floating Point
19
FNC140-FNC149
Data
Operation 2
20
FNC150-FNC159
Positioning
Control
- The exponent part is fixed to 2 digits.
When the exponent part is 1 digit, "30H (0)" is stored after the sign of the exponent part.
- "00H" or "0000H" is automatically stored at the end of the converted character string.
Related instructions
Errors
An operation error is caused in the following cases; The error flag M8067 turns ON, and the error code is
stored in D8067.
When is not located within the following range (error code: K6706)
0, ±2
126
≤< ±2
128
When the format specified by is any value other than "0" or "1" (error code: K6706)
When the total number of digits specified by +1 is not located within the following range (error code:
K6706)
In the case of decimal point format:
When the number of digits of the decimal part is "0", Total number of digits 2
When the number of digits of the decimal part is any value other than "0", Total number of digits
(Number of digits of decimal part + 3)
In the case of exponent format:
When the number of digits of the decimal part is "0", Total number of digits 6
When the number of digits of the decimal part is any value other than "0", Total number of digits
(Number of digits of decimal part + 7)
When the number of digits of the decimal part specified by +2 is not located within the following
range (error code: K6706)
In the case of decimal point format: Number of digits of decimal part (Total number of digits - 3)
In the case of exponent format: Number of digits of decimal part (Total number of digits - 7)
When the devices storing a character string specified by exceeds the allowable device range (error
code: K6706)
When the conversion result exceeds the specified total number of digits (error code: K6706)
Instruction Description
EVAL (FNC117) Converts a character string (ASCII codes) into binary floating point data.
STR (FNC200) Converts binary data into a character string (ASCII codes).
VAL (FNC201) Converts a character string (ASCII codes) into binary data.
1
12
4
+1
+2
Total number of digits (12)
0
"30H (0)" is stored.
2 3 4 6 E + 11
Fixed to 2 digits.
+1
12.34567
S
1
S
1
S
2
S
2
S
2
S
1
S
1
S
2
S
2
S
2
D

Table of Contents

Related product manuals