FX3G/FX3U/FX3UC Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
21 Real Time Clock Control – FNC160 to FNC169
21.2 FNC161 – TZCP / RTC Data Zone Compare
21
FNC160-FNC169
Real Time Clock
Control
22
FNC170-FNC179
External Device
23
FNC180
Alternate
Instructions
24
FNC181-FNC189
Others
25
FNC190-FNC199
Block Data
Operation
26
FNC200-FNC209
Character String
Control
27
FNC210-FNC219
Data
Operation 3
28
FNC220-FNC249
Data
Comparison
29
FNC250-FNC269
Data Table
Operation
30
FNC270-FNC274
Ex-Device
Inverter Comms
Program example
Turns ON in the case of " ".
Turns ON in the case of " ".
Turns ON in the case of " ".
The setting range of "hour" is from 0 to 23.
The setting range of "minute" is from 0 to 59.
The setting range of "second" is from 0 to 59.
S
1
: Specify the lower limit of the comparison time zone in "hour", "minute" and "second.
S
1
+1 and +2S
1
,
S
2
S
2
+1 and
S
2
+2
, : Specify the upper limit of the comparison time zone in "hour", "minute" and "second.
S
S
+1 and +2S
, : Specify the time data in "hour", "minute" and "second.
+1 and +2D
D
D
, : Turn ON or OFF according to the comparison result.
X000
FNC161
TZCP
D 20 D 30 D 0 M 3
S
1
S
2
S
D
M3
>
M4
M5
↑
Even if X000 is OFF and TZCP instruction is not executed, M0
to M2 hold the status before X000 turned OFF.
D1 (minute)
D0 (hour)
D2 (second)
D21 (minute)
D20 (hour)
D22 (second)
D 31 (minute)
D 30 (hour)
D 32 (second)
≤≤
>
D21 (minute)
D20 (hour)
D22 (second)
D1 (minute)
D0 (hour)
D2 (second)
D1 (minute)
D0 (hour)
D2 (second)
D 31 (minute)
D 30 (hour)
D 32 (second)