4)Change the current program inside the PLC to the program shown in “Cautions on using a memory
cassette” in “Cautions” on the previous page.
5)To the PLC, write the data which was temporarily withdrawn to GX Developer.
[1]Select “Online” → “Write to PLC...” to
display the “Write to PLC” window.
[2]Click “PLC parameter” and “MAIN” to put
a check mark to each of them.
[3]Click [Execute] button to execute writing.
*2.For Ver. 8.13P to 8.24A of GX Developer, the PLC
type is FX
3UC.
6)Change the PLC mode from STOP to RUN, execute the program, and store the data to the extension file
registers inside the memory cassette.
FX3U(C)*2