951
FX3G/FX3U/FX3UC Series Programmable Controllers
Programming Manual - Basic & Applied Instruction Edition
A Programming Tool Applicability and Version Upgrade History
A-1 Programming Tool Applicability
31
FNC275-FNC279
Data
Transfer 3
32
FNC280-FNC289
High Speed
Processing 2
33
FNC290-FNC299
Extension File
Register
34
FNC300-FNC305
FX
3U
-CF-ADP
35
SFC•STL
Programming
36
Interrupt
Function
37
Special Device
38
Error Code
A
Version Up
Information
B
Execution Times
Cautions on writing during RUN
Item Caution
Program memory which can be
written in RUN mode
Built-in RAM and optional memory cassette (whose write protect switch is set to OFF)
Number of
program
steps which
can be written
for circuit
change in
RUN mode
GX Developer
Ver.8.72A or later
•For FX
3G PLCs
256 steps or less after edit (addition/deletion) (including NOP immediately after circuit
blocks except final circuit
GX Developer
Ver.8.23Z or later
•For FX
3U/FX3UC PLCs Ver.2.20 or later
256 steps or less after edit (addition/deletion) (including NOP immediately after circuit
blocks except final circuit)
•For FX
3UC PLCs earlier than Ver.2.20
127 steps or less after edit (addition/deletion) (including NOP immediately after circuit
blocks except final circuit)
GX Developer
Ver.8.22Y and earlier
FX-PCS/WIN(-E)
127 steps or less after edit (addition/deletion) (including NOP immediately after circuit
blocks except final circuit)
Circuit blocks which cannot be written
during RUN
Circuit blocks in which labels P and I are added, deleted or changed in edited circuits
Circuit blocks in which 1-ms timers (T246 to T249 and T256 to T511) are added in edited circuits
Circuit blocks in which the following instructions are included in edited circuits
Instruction to output high speed counters C235 to C255 (OUT instruction)
SORT2 (FNC149), TBL (FNC152), RBFM (FNC278) and/or WBFM (FNC279) instruction
Circuit blooks which require attention
on operation after writing during RUN
During RUN, avoid writing to a circuit block including the following instructions under
execution. If writing is executed during RUN to such a circuit block, the PLC decelerates
and stops pulse output.
DSZR (FNC150), DVIT (FNC151), ZRN (FNC156), PLSV (FNC157) instruction [with
acceleration/deceleration operation], DRVI (FNC158) and/or DRVA (FNC159) instruction
During RUN, avoid writing to a circuit block including the following instruction under
execution. If writing is executed during RUN to such a circuit block, the PLC immediately
stops pulse output.
PLSV (FNC157) instruction [without acceleration/deceleration operation]
During RUN, avoid writing to a circuit block including the following instructions under
execution of communication. If write during RUN is executed to such a circuit block, the
PLC may stop communication after that.
If the PLC stops communication, set the PLC to the STOP mode once, and then set it to the
RUN mode again.
IVCK (FNC270), IVDR (FNC271), IVRD (FNC272), IVWR (FNC273) and/or IVBWR
(FNC274) instruction
During RUN, avoid writing to a circuit block including the following instruction under execution.
If such writing is executed during RUN, instructions being executed are canceled.
FLCRT (FNC300), FLDEL (FNC301), FLWR (FNC302), FLRD (FNC303),
FLCMD (FNC304) and/or FLSTRD (FNC305) instruction