26 PARAMETER SETTING
26.2 Module Parameters
427
26
*1 It can be set only on the CH1 side. When the test mode is selected, the communication protocol setting on the CH1 side and the setting
on the CH2 side cannot be configured (will be invalid).
*2 It will be enabled only when "MELSOFT Connection" is selected for the communication protocol setting.
*3 It can be set on the CH2 side only. (Since the linked operation is not available for RJ71C24-R2, it is fixed to "Independent".)
When it is set to "Interlink", the communication protocol setting for the CH2 side cannot be configured.
*4 Set to 8-bit for data communication using MC protocol (Format 5) or Bidirectional protocol.
*5 n: 1 to 10
Receiving area
specification
Receiving buffer memory start address
designation
Set the start address of the area used as the receive area. 1024 to 6911 (400H to
1AFFH),
9728 to 16383 (2600H to
3FFFH)
(Default (CH1): 1536 (600H))
(Default (CH2): 2560 (A00H))
Receiving buffer memory size
specification
Set the size of the area used as the receive area. 1 to 6656 (1H to 1A00H)
(Default: 512 (200H))
Conversion
designation
ASCII-binary conversion designation Set whether or not data to be communicated to a target
device is communicated with ASCII code.
Do not convert
•Convert
(Default: Do not convert)
Transparent code
designation_Trans
parent code for
sending
specification (nth)
*5
Transparent code Set one-byte data for transmission control.
Set '0' to both the transparent code and additional code
when the transparent code for sending is not specified.
00H to FFH
(Default: 00H: Do not specify
(The transparent code and
the additional code are 0
both.))
Additional code Set one-byte data added immediately before the
transparent code and additional code data.
Set the additional code within the range of 01H to FFH
when the transparent code for sending is specified.
Set '0' to both the transparent code and additional code
when it is not specified.
00H to FFH
(Default: 00H: Do not specify
(The transparent code and
the additional code are 0
both.))
Transparent code
designation_Trans
parent code for
receiving
specification
Transparent code Set one-byte data for transmission control.
Set '0' to both the transparent code and additional code
when the transparent code for receiving is not specified.
00H to FFH
(Default: 00H: Do not specify
(The transparent code and
the additional code are 0
both.))
Additional code Set one-byte data to be deleted at the data reception. (The
immediately succeeding one-byte data is processed for
reception.)
Set the additional code within the range of 01H to FFH
when the transparent code for receiving is specified.
Set '0' to both the transparent code and additional code
when it is not specified.
00H to FFH
(Default: 00H: Do not specify
(The transparent code and
the additional code are 0
both.))
Receiving end
specification
Receive end data quantity designation Set the receive end data quantity. 1 to 13310
(Default: 511)
Receive end code designation Set a receive end code.
0D0AH: CR, LF
00H to FFH: Arbitrary receive end code
FFFFH: No designation
0000H to 00FFH, 0D0AH,
FFFFH
(Default: 0D0AH: CR, LF)
Protocol execution history specification option Set whether execution logs of all protocol are stored or
whether execution logs of only abnormally completed
protocol are stored.
Only protocol that
completed abnormally
All protocol execution
status and execution
history
(Default: Only protocol that
completed abnormally)
Item Description Setting range