3 DATA COMMUNICATION USING NONPROCEDURAL PROTOCOL
3.1 Receiving Data from Target Device
59
3
Reception operation
Data reception when the receive data storage area > receive data length
Ex.
When data of 511 words or less is received by the CH1 side interface on the condition that the receive area for the CH1
interface is Un\G1536 to 2047 (default value)
Data reception when the receive data storage area < receive data length (Reception using the
receive end code)
The data link processing is required in the program.
Ex.
When data of 534 words is received by the CH1 side interface on the condition that the receive area for the CH1 interface is
Un\G1536 to 2047 (default value).
INPUT
Complete code
Target device
100 words
C24
Reception data read request (X3)
Program
Number of data to be read: 100 words
INPUT INPUT
Complete code
Target device
511 words 23 words
C24
Reception data read request (X3)
Program
Number of data to be read:
511 words
Number of data to be read:
23 words