6 OPTIONS AND PERIPHERAL EQUIPMENT
6.17 MR-J3-D05 safety logic unit
243
6
Connecting wires
1. Check the model numbers of the housing, contact, and tool to be used.
2. Insert the tool diagonally in relation to the terminal block.
3. Insert the tool until it touches the surface of the terminal block. The tool becomes perpendicular to the terminal block at
this point.
4. Insert the wire until it reaches the stop. When doing so, slightly twist the core wire so that it does not fray.
It is easier to insert the wire by inserting it diagonally while twisting the tool a little.
5. Pull out the tool.