58
3 SIGNALS AND WIRING
3.3 Explanation of power supply system
Wiring CNP1, CNP2, and CNP3
• For the wire sizes, refer to the following.
Page 197 Selection example of wires
• When wiring, remove the power connectors from the servo amplifier.
• Insert only one wire or ferrule into each wire insertion hole on each power connector.
To wire to CNP1, CNP2 and CNP3, use the servo amplifier power connectors that came with the amplifier.
Connector
■MR-J5-10_ to MR-J5-100_
■MR-J5-200_/MR-J5-350_
Connector Receptacle assembly Applicable wire Stripped length
[mm]
Open tool Manufacturer
Size Insulator OD
CNP1 06JFAT-SAXGDK-K7.5 (LA) AWG 18 to 14 3.9 mm or less 9 J-FAT-OT-K JST
CNP2 05JFAT-SAXGDK-K5.0 (LA)
CNP3 03JFAT-SAXGDK-K7.5 (LA)
Connector Receptacle assembly Applicable wire Stripped length
[mm]
Open tool Manufacturer
Size Insulator OD
CNP1 06JFAT-SAXGFK-XL (LA) AWG 16 to 10 4.7 mm or less 11.5 J-FAT-OT-EXL JST
CNP2 05JFAT-SAXGDK-H5.0 (LA) AWG 18 to 14 3.9 mm or less 9
CNP3 03JFAT-SAXGFK-XL (LA) AWG 16 to 10 4.7 mm or less 11.5
CNP2
CNP1
CNP3
CNP2
CNP1
CNP3