6 OPTIONS AND PERIPHERAL EQUIPMENT
6.3 MR-CM simple converter
173
6
6.3 MR-CM simple converter
Combination of simple converter and servo amplifier
Selection method
Select a servo amplifier for connection that meets the following conditions.
Connectable servo amplifier models
MR-J5-10_ to MR-J5-200_, MR-J5W2-22G_ to MR-J5W2-1010G_, MR-J5W3-222G_/MR-J5W3-444G_
The sum of rated capacities of connected servo amplifiers [kW] 3 kW (MR-CM3K rated output)
For multi-axis servo amplifiers, the calculation uses the sum of the rated capacities of all axes as the rated capacity of one
servo amplifier.
Number of connectable servo amplifiers to one MR-CM3K 6
A multi-axis servo amplifier is counted as one servo amplifier unit, rather than the number of axes.
Servo amplifier setting when using a simple converter
When using a simple converter, set [Pr. PA02.4] of the servo amplifier connected in the latter stage to "1" (simple converter is
used). If the simple converter is used without setting [Pr. PA02.4], unexpected alarms may occur.
The simple converter and the external regenerative option connected to the servo amplifier can be used together. To use an
external regenerative option, set [Pr. PA02.0-1]. Note that the simple converter does not have a regenerative function. Also,
an external regenerative option cannot be connected to the simple converter.
Simple converter standard specifications
*1 The value when a 3-phase power supply input is used
Model MR-CM3K
Converter output Rated voltage 270 V DC to 324 V DC
Rated current 20 A
*1
Main circuit power supply
input
Voltage/Frequency 3-phase 200 V AC to 240 V AC, 50/60 Hz
Rated current 16 A
*1
Permissible voltage fluctuation 3-phase 170 V AC to 264 V AC
Overheat detection
function
Thermal sensor The contact between TH1 and TH2 opens if abnormal overheating occurs.
Contact
specifications
Maximum voltage 110 V AC/DC
Maximum current 0.3 A/20 V DC
Minimum current 0.1 mA/1 V DC
Maximum capacity 6 VA
Applicable servo amplifier MR-J5-10_ to MR-J5-200_
MR-J5W2-22G_ to MR-J5W2-1010G_
MR-J5W3-222G_, MR-J5W3-444G_
Maximum number of connectable servo amplifiers 6
Total capacity of connectable servo amplifiers 3 kW
Continuous rating 3 kW
Instantaneous maximum rating 9 kW
IP rating IP20
Close mounting 3-phase power supply input Possible
Mass 0.7 kg
Wire size L1/L2/L3/PE 2 mm
2
to 3.5 mm
2
(AWG 14 to 12)
P4/N- 2 mm
2
to 3.5 mm
2
(AWG 14 to 12)
Total wiring length from P4/N- of simple converter to P4/N- of servo
amplifier
5 m or less