1 INTRODUCTION
1.3 Wiring check
23
1
Connecting the servo amplifier to the servo motor
Check that the phases (U/V/W) of the servo amplifier power outputs and the phases (U/V/W) of the servo motor power
inputs match with each other.
MR-J5-_G_/MR-J5-_A_
MR-J5W_-_G_
Check that the power to be supplied to the servo amplifier is not connected to the power outputs (U/V/W) as doing so will
cause the servo amplifier and the servo motor to malfunction.
Check that the grounding terminal of the servo motor is connected to the PE terminal of the servo amplifier.
Check that the CN2 connector of the servo amplifier is securely connected to the encoder of the servo motor using a motor
cable or encoder cable.
U
MV
W
U
V
W
Servo amplifier Servo motor
CNP3A
CNP3B
CNP3C
U
V
W
M
U
V
W
M
U
V
E
E
E
W
M
U
V
W
U
V
W
U
V
W
Servo amplifier A-axis servo motor
B-axis servo motor
C-axis servo motor
M
U
V
W
U
V
W
L1
L2
L3
Servo amplifier Servo motor
M
E
Servo amplifier Servo motor