348
10 USING A LINEAR SERVO MOTOR
10.4 Basic functions
For data set type homing
For data set type homing, when CR (Clear) is turned on, the position control counter is cleared and the current position is
stored in the non-volatile memory (backup memory) as home position data.
*1 This can be changed with [Pr. PL01].
ON
OFF
1048576 pulses
*1
0 mm/s
Linear servo
motor speed
CR (Clear)
Reference
home position
Linear servo
motor position
Home position
Linear encoder home position