eased so as
to
move the shifter and the guide-bush, and
the
control-rack
will
be also moved
toward the
fu
II-load.
In
case when
the
r.p.m.
is
extremely lowered, the weak start-spring
will
also
begin
to
act
to
pull
the
control-rack swiftly toward the full-load and the specified r.p.m. may
be
maintained.
3.
Controlling process
at
the highest rotation
(Fig.
6)
I n case when
the
engine at a certain r.p.m. fixed by
the
control
lever
is
affected by load
or remains non-load, the governor, excepting the case of
over-load,
will
maintain the
adjustment
of
rotation within the limit which
is
fixed by the changing rate. Let it be
supposed
that
a driver
moves
the control-lever from the idling position to a position where
the proper speed
will
be obtained through the link by working the pedals (Fig. 6);
in
this
case. The tension
of
the governor spring and the moment arm concerning the revolving
center of the tension-lever are increased, the governor-spring
pulls back the tension-lever
until it comes
in
touch with the full-load stopper and the tension-lever pushes the shifter and
guide-bush
to
the side of the injection pump
by
pushing them.
FuI-load
Ungleich-Str
ok.
Fig. 6
The
starting
of
the
Ungleich
at
the
low
r.p.m. full-load
-