7.4.2 Recipe Settings 
The recipe settings for the station number 1 to 16 have been set with the recipe number 12001 to 12016. When the 
network number and the station number are changed, setting of the devices registered in the recipe settings also 
need to be changed. 
 
(1)   Change devices of recipe settings using [Device Batch Edit] in GT Designer3. 
In GT Designer3, go to [Search/Replace] – [Batch Edit] and select [Device] and make changes from the [Device 
Batch Edit] dialog.  
1. Select [Project] under [Target]. 
2. Select [Range] under [Display Type]. 
3. Click [Find Now]. 
4. Input the network number and station number you wish to change in the [After] column under search    
result list. 
5. Click [Replace]. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 Open the [Device] tab of the station number in the recipe setting for the station number you are changing and 
confirm that the devices have been changed. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
4. Change to the new network 
number and station number 
Recipe device for each station number. 
The  start  device  is  the  network number and 
the station number.