7.4 Changing the Inverter Network No. and Station No.
Apply the settings below in order to change the inverter network number and station number.
7.4.1 Switches in W-12010 Station Number Switching Window
(1) Open the [Station No. Switching] under [Action List] and change the network number and station number.
(2) Change the [Constant] of the [Lamp] function to the same network number and station number that have been
changed in (1)*1.
*1 The structure of the value stored in the station number switching device is
as below.
Set the constant in hexadecimal format.
• Upper 8 bits: Network No.
• Lower 8 bits: Station No.
Example: Network No. 1 and Station No. 25
01 25
Station No.
Network No.
Enter the constant
according to the new
network number and
station number
Enter the new network
number and station
number.