8
4.1   Adjustment flow for trial operation
Carry out the following start-up adjustment as the preparatory step for the automatic operation.
4.2   Initial setting
Select the items using the     and     keys.  
Press the [Enter] key to finalize the setting.
Then, switch the screens using the   and   keys.  
When the setting of the items marked with "" is not changed, 
switch the screens using the   and   keys without press-
ing the [Enter] key.
Check by automatic 
operation
     Operational check
(1) (2)
(5)
(4)
(6)
(7)
(3)
             Controller
* Initial setting
* Adjust tension detectors
Check the driving 
system in manual 
operation mode
Controller 
installation and 
wiring
Operating parameter 
adjustment as necessary
     See page 26 and after.
Completion of 
adjustment
Check for abnormalities when 
error occurs.
     See pages  75 through 77.
See pages 8 through 10.
W X
T
S
T S
Power ON
P S S W . E N T .
S E T → # # # # E N T E R P A S S W O R D#
A
T S N . U N I T S E L E C T T E N T I O N U N I T
 × 10 N :  N
N
T
S A R T T H E I N I T I A L
O R C H A N G E T O M
T
When the power is turned on, the version display screen appears for a few seconds.
The password "4095" is originally registered. When a password other 
than this is used, enter the new password on the "Password registration" 
screen and press the [Enter] key to register it. Both the newly registered 
password and the original value "4095" are valid.
T
T
L - 4 0 M T B - T e n s i o n C o n t r o l l e rE V e r . V # . # #
C o p y r i g h t M I T S U B I S H I E L E C T R I C C O R P .
E
4. Basics of adjustment and operation