37
When entering settings externally by analog voltage, prohibit the settings change from the panel.  This 
makes the setting value change only by the external analog input (controller installed externally) valid.
To set setting prohibition, use the "INH.ENT." screen within "OTHERS" on the engineer screen.
8.1   Varies set tension
• Instead of setting the tension from the panel, input signal of 0 
to 5V can be used for the tension setting.
When the input of 0 to  5V is given the tension setting value 
becomes 0 to 100%.
• Connect the signal to the terminal A11 as per the figure at 
right.
The tension setting from the panel or the tension setting by the 
external input, whichever is greater, becomes valid.  See the 
notes above.
• By setting “EXT.TENS.” to the MC5 or MC6, turning on or off the MC5 or MC6 can switch over the ten-
sion setting method sa follows.
• ON ----------External input is valid.
• OFF---------Setting form the panel is valid.
8.2   Enters reel diameter data
Refer to page 30 Section 7.4 "External reel diameter taper control".
Regarding the tension setting , stall setting, new reel presetting and taper ratio setting , the 
setting through the panel or the setting by external analog  input , whichever is greater , takes 
precedence in shipping -setting condition . By prohibiting change of the setting value from the 
panel on the  "Setting prohibited " screen, only the external analog input  (controller installed 
externally) is made valid.
If prohibited to change setting value from the panel , the setting value from the panel will be fixed 
at the value immediately before the prohibition .
Notes
1.  Setting
I H . E N T . I N H I B I T P A N E L E N T R Y
 T N S N . S E T :  S T A L L S E T :  N E W S E T :  T A P E R S E TR
N
If "Stall set" prohibition has made valid, the stall setting change 
from the panel will be prohibited. The setting value will be fixed 
at the value immediately before the prohibition.
1.  Connection
AIC
100kΩ
Ecternal 
tension 
setting
+5V
AI1
2.  Display
T S N . S E T E X T . M N T . →
S E T → # # # # N →
N                
               
If the external analog input is valid, message "EXT." appears on 
the "Tension set" screen as shown below.  If "EXT." is gone, the 
key setting is greater and is therefore valid.
3.  Change over the tension setting method
M 5 S E L E C T M C 5 I N P U T
 E X T . T E N S .I N C H N G :  O U T R M T . :  C U T T R Q . :
C
Select " EXT.TENS. "
8. Use of external analog signals