40
9.1   Records tension data
Corresponding to the tension detection from zero to full scale, 
the output from 0 to 5V is generated.  The  full scale tension 
is set by the parameter.
• Connect this signal between TMO and AOC.
• The load resistance should be 1 kΩ or greater.
• The output filter can be adjusted to 1/4, 1/2, 1, 2 or 4 seconds by the parameter.
• To change the response characteristic of the TMO tension monitor output, select "TMO FLT." within 
"TENSION" on the engineer screen.  Increasing the value slows the response characteristic.
9.2   Monitors input and output condition
To check condition of the contacts and analog data input and output, use the "CONTACTS" screen or similar 
one within "OTHERS" on the engineer screen.
TMO
AOC
Tension meter
recorder
Load 
resistance 
1k Ω or more
0~5V
1.  Connection
2.  Setting
T O F L T . S E T T M O O U T P U T F I L T E R
 1 / 4 s :  1 / 2 s :  1 s : 2 s :  4 s
M
T
T
( Analog input monitor screen )
( Analog output monitor screen )
( Contact  input / Output monitor screen )
C N T A C T S C O N T A C T S M O N I T O R
 M C 1 :  M C 2 :  M C 3 :  M C 4 :  M C 5  M C 6 :  Z T:
O
M N I T O R 1 S I G N A L I N P U T M O N I T O R
A I 1 → # . # V : A I 2 → # . # V : A I 3 → # . # V
O
M N I T O R 2 S I G N A L O U T P U T M O N I T O R
S A → # . # V : T M O → # . # V : N R O → # . # V
O
M M N T . 1 L E - 4 0 M D C O N T A C T I N P U T M O N I T O R
 R U N :  B W D :  D R S T :  L R S T :  M E M :  P D R V :  R C H
D
( When connected to LE-40MD )
T
R E L R E V . R E E L R E V O L U T I O N S I G N A L M O N I T O R
R O T A → # # # # % : T O T B → # # # # %
E
T
M M N T . 2 L E - 4 0 M D C O N T A C T O U T P U T M O N I T O R
 Y 1 :  Y 2 :  Y 3 :  S N C R
D
( Contact input to LE-40MD monitor screen )
( Reel rotation velocity output monitor screen )
( Contact output from LE-40MD monitor screen )
9. Other functions