53
After the data processing is completed in the LE-40MTB-E, the X0 is turned on while the M907  is turned 
off, then all set value are transferred at a time to the temporary buffers for link.
After the data processing is completed in the LE-40MTB-E, the X1 is turned on while the M907 is turned 
off, then the set values other than X1=ON are transferred to the temporary buffers for link.
When the X0 is turned on, the data is transferred from the temporary buffers for link D0Å`D10 to the link 
data transfer area D490Å`D499, then the sending start flag M807 is turned on.
When the receiving completion flag M907 is turned on by the LE-40MTB-E, sending is completed.
7. Example of program
The link data is transferred to the buffer
Setting of the decimal point of the full scale 
tension
M8000
X000 M906
( M8070 ) Master station
 H
MOV  0009  D1
 K
MOV  50    D0
 H
MOV  0004  D3
  H
MOV  0004  D7
 K
MOV  54    D2
 K
MOV  56    D4
K
MOV  500   D5
K
MOV  57    D6
  H
MOV  0000  D8
  H
MOV  0000  D9
  K
MOV  250   D1
 K
MOV  1     D0
 K
MOV  20    D3
 K
MOV  50    D7
 K
MOV  2     D2
 K
MOV  15    D4
 K
MOV  25    D5
 K
MOV  16    D6
 K
MOV  20    D8
 K
MOV  120   D9
               K
BMOV D0 D490  10
[ PLS  M0 ]
[ SET  M807 ]
[ RST  M807 ]
[ END ]
X001 M907
X010 M807
M0 M907
CIRCUIT END
M907
0
3
53
107
111
123
Setting of the memory 
switch 1
Unit = N, multi reels control.
Setting of the 
MC5
OUT remote
Setting of the fill scale 
tension
500
×0.1
The data is not transferred
Data 0
Tension setting
25.0N
Stall setting
20%
Manual setting
25%
Start timer setting
5.0 s
Gain 1 setting
120%
End of program