53
After the data processing is completed in the LE-40MTB-E, the X0 is turned on while the M907 is turned
off, then all set value are transferred at a time to the temporary buffers for link.
After the data processing is completed in the LE-40MTB-E, the X1 is turned on while the M907 is turned
off, then the set values other than X1=ON are transferred to the temporary buffers for link.
When the X0 is turned on, the data is transferred from the temporary buffers for link D0Å`D10 to the link
data transfer area D490Å`D499, then the sending start flag M807 is turned on.
When the receiving completion flag M907 is turned on by the LE-40MTB-E, sending is completed.
7. Example of program
The link data is transferred to the buffer
Setting of the decimal point of the full scale
tension
M8000
X000 M906
( M8070 ) Master station
H
MOV 0009 D1
K
MOV 50 D0
H
MOV 0004 D3
H
MOV 0004 D7
K
MOV 54 D2
K
MOV 56 D4
K
MOV 500 D5
K
MOV 57 D6
H
MOV 0000 D8
H
MOV 0000 D9
K
MOV 250 D1
K
MOV 1 D0
K
MOV 20 D3
K
MOV 50 D7
K
MOV 2 D2
K
MOV 15 D4
K
MOV 25 D5
K
MOV 16 D6
K
MOV 20 D8
K
MOV 120 D9
K
BMOV D0 D490 10
[ PLS M0 ]
[ SET M807 ]
[ RST M807 ]
[ END ]
X001 M907
X010 M807
M0 M907
CIRCUIT END
M907
0
3
53
107
111
123
Setting of the memory
switch 1
Unit = N, multi reels control.
Setting of the
MC5
OUT remote
Setting of the fill scale
tension
500
×0.1
The data is not transferred
Data 0
Tension setting
25.0N
Stall setting
20
Manual setting
25
Start timer setting
5.0 s
Gain 1 setting
120
End of program