3. Setup
3 - 44
Standard specifications
No. Abbrev. Parameter name Explanation
Setting range
(Unit)
bit Explanation
8
9
A
ent
B
Set the detector type.
Set the position detector type for “pen”, and the speed detector type
for “ent”. In the case of the semi-closed loop control, set the same
value for “pen” and “ent”.
C
pen
setting
ent setting Detector model name
D 0 0 OSE104
E
pen
1 1 OSA104
F 2 2 OSE105, OSA105
3 3
4 Setting impossible OHE25K-ET, OSE104-ET
5 Setting impossible OHA25K-ET, OSA104-ET
6 Setting impossible OSE105-ET, OSA105-ET
SV025 MTYP* Motor/Detector type
7 Setting impossible
8 Setting impossible
Relative position detection scale, MP type
(Mitsubishi Heavy Industries)
9 Setting impossible
AT41 (Mitsutoyo), FME type, FLE type
(Futaba)
A Setting impossible AT342 (Mitsutoyo)
B Setting impossible
C
C
(Current
synchronization)
The setting of the slave axis in the speed/current
synchronization control.
When the master axis is the semi-closed control.
D Setting impossible
E Setting impossible
F Setting impossible
SV026 OD2
Excessive error
detection width
during servo OFF
Set the excessive error detection width when servo ON.
For the standard setting, refer to the explanation of SV023 (OD1).
When “0” is set, the excessive error detection will not be performed.
0 to 32767
(mm)