2. Wiring and Connection
2 - 27
2-4-4 Connection of the spindle motor
Refer to each motor specifications for details on the motor side connection destination, specifications
and outline, and for the spindle PLG detector specifications.
(1) Connecting the motor built-in PLG
U V W
Max. 30m
CN5
Spindle motor
MDS-C1-SP
Power cable
Cooling fan terminal
block (BU,BV,BW)
Grounding terminal
Motor power terminal
block (U,V,W)
Example for 3-phase cooling fan
p
ower su
pp
l
y
(Note) Either a single-phase or 3-phase power supply is used for the cooling fan.
Refer to the Spindle Motor Specifications for details.
Option cable : CNP5S
BU BV BW
U V W