5. Spindle Adjustment
5 - 2
5-1 D/A output specifications for spindle drive unit
The MDS-C1-SP/SPH/SPX/SPHX/SPM spindle drive unit has a function to D/A output each control
data. The spindle adjustment data required to set the spindle parameters matching the machine can be
D/A output. The data can be measured with a hi-corder or oscilloscope, etc.
5-1-1 D/A output specifications
5-1-2 Setting the output data
No. Abbrev. Parameter name Explanation
SP253 DA1NO
D/A output channel 1 data No.
Input the No. of the data to be output to each D/A output channel.
SP254 DA2NO
D/A output channel 2 data No.
No. Output data Original data unit
Output magnification
standard setting value
(SP255, SP256)
Output unit for
standard setting
Output
cycle
ch1: Speedometer output 10V=max. speed (Zero=0V) 0
Depends on maximum
speed
3.55ms
0
ch2: Load meter output 10V=120% load (Zero=0V) 0 30-minute rating 12%/V 3.55ms
1
2 Current command Rated 100%=4096 8 30-minute rating 20%/V 3.55ms
3 Current feedback Rated 100%=4096 8 30-minute rating 20%/V 3.55ms
4 Speed feedback r/min 13 500r/min/V 3.55ms
5
6 Position droop
1deg=(64000÷65536)
671 10deg/V 888µs
7
8
Feedrate (FT) 1deg=(64000÷65536)
629
(at 3.5ms communication)
500r/min/V 888µs
9
10 Position command
1deg=(64000÷65536)
19 (18.64) 360deg/V 888µs
11
12 Position feedback
1deg=(64000÷65536)
19 (18.64) 360deg/V 888µs
13
80 Control input 1
81 Control input 2
82 Control input 3
83 Control input 4
84 Control output 1
HEX Bit correspondence 3.55ms
85 Control output 2
86 Control output 3
87 Control output 4
125
Test output saw tooth wave
0 (256) Cycle: 227.5ms 444µs
126
Test output oblong wave
0 (256) Cycle: 1.7ms 444µs
127
Test output 2.5V (data 0)
0 (256) - 444µs
Item Explanation
No. of channels 2ch
Output cycle 444µs (min. value)
Output
precision
8bit
Output voltage
range
0V to +5V (zero) to +10V,
0V to +10V for meter output
Output
magnification
setting
±1/256 to ±128-fold
Output pin
CN9 connector
MO1 = Pin 9
MO2 = Pin 19
GND = Pin 1
Function
Phase current feedback output function
U phase current FB : Pin 7
V phase current FB : Pin 17
DS-C1-SP
MO19
Name
LG
UIFB
2
5
1
Pin
6
4
3
10
7
8
CN9 connector
MO2 19
Name
VIFB
12
15
11
Pin
16
14
13
20
17
18