Appendix 3. EMC Installation Guidelines
A3 - 8
Appendix 3-6 EMC countermeasure parts
Appendix 3-6-1 Shield clamp fitting
The effect can be enhanced by connecting the cable directly to the earthing plate.
Install an earthing plate near each panel's outlet (within 10cm), and press the cable against the earthing
plate with the clamp fitting.
If the cables are thin, several can be bundled and clamped together.
Securely earth the earthing plate with the frame ground. Install directly on the cabinet or connect with an
earthing wire.
Contact Mitsubishi if the earthing plate and clamp fitting set (AERSBAN- SET) is required.
Note 1) Screw hole for wiring to earthing plate in cabinet.
Note 2) The earthing plate thickness is 1.6mm.
A B C Enclosed fittings L
AERSBAN-DSET 100 86 30
Clamp fitting A × 2
Clamp fitting A 70
AERSBAN-ESET 70 56
Clamp fitting B × 1
Clamp fitting B 45
View of clamp section