3. Setup
3 - 53
M60S
Series
No.
Abbrev. Parameter name Details
Setting range
(Unit)
3021 sori
Orientation
rotation speed
Set the spindle orientation rotation speed.
Set the rotation speed for when the spindle rotates at the constant
rotation speed.
0 to 32767
(r/min)
3022 sgear
Encoder gear ratio Set the gear ratio of the spindle to the encoder. 0: 1/1
1: 1/2
2: 1/4
3: 1/8
3023 smini
Minimum rotation
speed
Set the minimum rotation speed of the spindle.
If an S command instructs the rotation speed below this setting, the
spindle rotates at the minimum rotation speed set by this parameter.
0 to 32767
(r/min)
3024 sout*
Spindle
connection
Set the type of the spindle to be connected.
0: No connection with the spindle
1: Serial connection (bus)
2 to 5: Analog output
0 to 5
3025 enc-on
Spindle encoder Set connection information of the spindle encoder.
0: No connection
1: Spindle connection (Spindle encoder connection check function
valid.)
2: Serial connection of encoder
0 to 2
3026 cs_ori
Selection of coil in
orientation mode
0: Perform orientation using the coil selected when the orientation
command is issued.
1: Use coil L whenever the orientation command is issued.
0/1
3027 cs_syn
Selection of coil in
spindle
synchronous
mode
0: The coil H/L is selected by the actual spindle motor rotation speed
(calculated from commanded rotation speed) when spindle
synchronous control starts. (The coil is not switched during
synchronous control. The control is carried out with the coil selected
at start.)
If the actual spindle motor rotation speed is less than SP020, the coil
L is selected, and if more than the value, the coil H is selected.
1: Use coil H whenever the spindle synchronous command is issued.
0/1
3028 sprcmm
L system tap cycle
spindle forward
run/
reverse run M
command
Set the M code of the spindle forward run/reverse run command.
High-order three digits: The spindle forward run command's M code is
set.
Low-order three digits: The spindle reverse run command's M code is
set.
0 to 999999
3029 tapusel
Asynchronous tap
gear selection
Specify whether to use the tap rotation speed or maximum rotation
speed for the gear that is selected when an asynchronous tap command
is issued.
0: Tap rotation speed
1: Maximum rotation speed
This parameter is valid only when the M-function synchronous tap cycle
enable parameter (#1272 ext08 bit1) is ON.
0/1
3030 mbsel *
Selection of
magnetic bearings
Select whether to use magnetic bearings.
0: Magnetic bearings invalid
1: Magnetic bearings valid
0/1
3031
smcp_no *
Drive unit I/F
channel No.
(spindle)
Using a 4-digit number, set the drive unit interface channel No. and
which axis in that channel is to be used when connecting a spindle drive.
High-order two digits : Drive unit interface channel No.
Low-order two digits : Axis No.
When using the conventional fixed layout, set all axes to "0000".
Set "0000" when using an analog spindle.
0000
0101 to 0107
0201 to 0207
3032
mbmcp_no *
Drive unit I/F
channel No.
(magnetic
bearing)
Using a 4-digit number, set the drive unit interface channel No. and
which axis in that channel is to be used when connecting a magnetic
bearing unit.
High-order two digits : Drive unit interface channel No.
Low-order two digits : Axis No.
When using the conventional fixed layout, set all axes to "0000".
0000
0101 to 0107
0201 to 0207
Parameters with an asterisk * in the abbreviation, such as sout*, are validated with the NC power turned ON again.