3. Setup 
 
 
 
3 - 55 
 
M60S 
Series 
No. 
Abbrev. Parameter name  Details 
Setting range
(Unit) 
3059 sptc6 
Spindle synchro- 
nization multi-step 
acceleration/ 
deceleration 
changeover 
speed 6 
Set the spindle speed for changing the 6th step's 
acceleration/deceleration time constant. 
0 to 99999 
(r/min) 
3060 sptc7 
Spindle synchro- 
nization multi-step 
acceleration/ 
deceleration 
changeover 
speed 7 
Set the spindle speed for changing the 7th step's 
acceleration/deceleration time constant. 
0 to 99999 
(r/min) 
3061 spdiv1 
Magnification for 
time constant 
changeover 
speed 1 
Set the acceleration/deceleration time constant between the spindle 
synchronization multi-step acceleration/deceleration changeover speed 
1 (sptc1) to the spindle synchronization multi-step acceleration/ 
deceleration changeover speed 2 (sptc2) as a magnification in respect to 
the spindle synchronization acceleration/deceleration time constant 
(spt). 
0 to 127 
3062 spdiv2 
Magnification for 
time constant 
changeover 
speed 2 
Set the acceleration/deceleration time constant between the spindle 
synchronization multi-step acceleration/deceleration changeover speed 
2 (sptc2) to the spindle synchronization multi-step 
acceleration/deceleration changeover speed 3 (sptc3) as a 
magnification in respect to the spindle synchronization 
acceleration/deceleration time constant (spt). 
0 to 127 
3063 spdiv3 
Magnification for 
time constant 
changeover 
speed 3 
Set the acceleration/deceleration time constant between the spindle 
synchronization multi-step acceleration/deceleration changeover speed 
3 (sptc3) to the spindle synchronization multi-step 
acceleration/deceleration changeover speed 4 (sptc4) as a 
magnification in respect to the spindle synchronization 
acceleration/deceleration time constant (spt). 
0 to 127 
3064 spdiv4 
Magnification for 
time constant 
changeover 
speed 4 
Set the acceleration/deceleration time constant between the spindle 
synchronization multi-step acceleration/deceleration changeover speed 
4 (sptc4) to the spindle synchronization multi-step 
acceleration/deceleration changeover speed 5 (sptc5) as a 
magnification in respect to the spindle synchronization 
acceleration/deceleration time constant (spt). 
0 to 127 
3065 spdiv5 
Magnification for 
time constant 
changeover 
speed 5 
Set the acceleration/deceleration time constant between the spindle 
synchronization multi-step acceleration/deceleration changeover speed 
5 (sptc5) to the spindle synchronization multi-step 
acceleration/deceleration changeover speed 6 (sptc6) as a 
magnification in respect to the spindle synchronization 
acceleration/deceleration time constant (spt). 
0 to 127 
3066 spdiv6 
Magnification for 
time constant 
changeover 
speed 6 
Set the acceleration/deceleration time constant between the spindle 
synchronization multi-step acceleration/deceleration changeover speed 
6 (sptc6) to the spindle synchronization multi-step 
acceleration/deceleration changeover speed 7 (sptc7) as a 
magnification in respect to the spindle synchronization 
acceleration/deceleration time constant (spt). 
0 to 127 
3067 spdiv7 
Magnification for 
time constant 
changeover 
speed 7 
Set the acceleration/deceleration time constant for the spindle 
synchronization multi-step acceleration/ 
deceleration changeover speed 7 (sptc7) and higher as a magnification 
in respect to the spindle synchronization acceleration/deceleration time 
constant (spt). 
0 to 127 
3068 symtm1 
Phase 
synchronization 
start confirmation 
time 
Set the time to confirm that synchronization is attained before phase 
synchronization control is started. 
When "0" is set, the time will be 2 seconds. When "100" or less is set, 
the time will be 100ms. 
0 to 9999 (ms)
3069 symtm2 
Phase 
synchronization 
end confirmation 
time 
Set the time to wait for phase synchronization control to end as the time 
for the rotation speed to reach the attainment range. 
When "0" is set, the time will be 2 seconds. When "100" or less is set, 
the time will be 100ms. 
0 to 9999 (ms)
3070 syprt 
Phase 
synchronization 
speed 
Set the fluctuation amount to change the synchronous spindle rotation 
speed during phase synchronization control as the command speed and 
rate. 
When "0" is set, the amount will be 100%. 
0 to 100 (%)
3071    (Not used.)  Not used. Set to "0".  0 