3. Setup
3 - 59
No. Abbr. Parameter name Details
<For MDS-C1-SPM>
FEDCBA98765 4 3 2 10
poff
ront
bit Meaning when set to 0 Meaning when set to 1 Standard
0 0
1 0
2 0
3 0
SP033 SFNC1* Spindle function 1
4 0
5 0
6 0
7 0
8 0
9 0
A 0
B This is used by Mitsubishi. Set to "0" unless particularly designated. 0
C ront Normal ready ON High-speed ready ON 0
D This is used by Mitsubishi. Set to "0" unless particularly designated. 0
E 0
F poff
Contactor hold at NC power OFF
invalid
Contactor hold at NC power OFF
valid
0
(Note) Set 0 if there is no particular explanation for the bit.
Parameters with an asterisk * in the abbreviation, such as OSP*, are validated with the NC power turned ON again.