Appendix 1. Cable and Connector Specifications
A1 - 3
(2) Detector cable
<CNV12 cable connection diagram>
This is an actual connection diagram for the CNV12 cable supplied by Mitsubishi. The connection
differs according to the cable length.
(20m or less) (20 to 30m)
<Cable manufacturing connection diagram>
Refer to the following connection diagram when manufacturing the cable. A cable up to 30m can be
manufactured.
CAUTION
1. Do not connect anything to pins unless particularly specified when
manufacturing a cable. (Leave OPEN)
2. Contact Mitsubishi when manufacturing a cable longer than 30m.
H
J
K
L
E
S
R
N
6
16
7
17
9
19
10
20
1
11
PE
SD
SD*
RQ
RQ*
BAT
P5(+5V)
LG
Plate
Drive unit side
Detector side
H
J
K
L
E
S
R
N
6
16
7
17
9
19
10
20
1
11
PE
SD
SD*
RQ
RQ*
BAT
P5(+5V)
LG
Plate
Drive unit side
Detector side
H
J
K
L
E
R
S
N
6
16
7
17
9
1
2
18
11
19
12
20
PE
SD
SD*
RQ
RQ*
BAT
LG
P5(+5V)
Plate
Drive unit side Detector side