9 - 40 9 - 40
MELSEC-Q
9 UTILITY PACKAGE (GX Configurator-SC)
[Test Items]
The following accumulated count of times counter values can be cleared to "0" by
the select test function.
Buffer memory address
Item
CH1 CH2
Reference section
Accumulated count of unlock process normal completion 22FBH
Accumulated count of unlock process abnormal completion 22FCH
Accumulated count of lock process based on circuit disconnection 22FFH
Callback permit accumulated count 22F0H
Callback denial accumulated count 22F1H
Auto (callback) connection permit accumulated count 22F2H
Auto (callback) connection denial accumulated count 22F3H
Accumulated count of callback receive procedure cancel 22F4H
User's Manual (Application)
[Operation procedure]
(Step 1) Display the "Modem function monitor/test" screen.
(Step 2) Click the setting value area of the item to be cleared to "0."
(Step 3) Click the " Execute test
."
The counter value of the selected item becomes "0."