2 - 19 2 - 19
MELSEC-Q
2 SYSTEM CONFIGURATION AND AVAILABLE FUNCTIONS
Function version of the Q series C24 Version of related product
Additional function
QJ71C24N
(-R2/R4)
QJ71C24 (-R2) CPU module GX Developer
GX
Configurator-
SC
GX Works2
Access to link direct device LW10000 or higher
using MC protocol
(QnA compatible 4C/3C frame only)
Function version B
or later whose first
5 digits of the serial
No. are 09043
Universal model
QCPU of function
version B or later
whose first 5 digits
of the serial No.
are 09042.
Access to extended data register D65536 or
higher, or extended link register W10000 or
higher using MC protocol
(QnA compatible 4C/3C/2C frame only)
Function version B
or later whose first
5 digits of the serial
No. are 09043
Universal model
QCPU of function
version B or later
whose first 5 digits
of the serial No.
are 09042.
Setting to buffer memories
Can be set in buffer
memory.
Function version B
or later, first 5 digits
of the serial No. are
10122 or greater
(The QJ71C24N(-
R4) only)
Monitor/Test
available
Version 2.18U
or later
Echo back
enable/disable
setting for RS-
422/485
interface
System registration to the flash
ROM
System registration
to flash ROM
available
Function version B
or later, first 5 digits
of the serial No. are
11062 or greater
(The QJ71C24N(-
R4) only)
System
registration into
the flash ROM
can be
performed.
Version 2.20W
or later
Version 1.31H
or later
Execution of the protocol
selected from the pre-defined
protocol library
Version 2.18U
or later
Execution of the created or
edited protocol
Function version B
or later, first 5 digits
of the serial No. are
10122 or greater
Addition of Sign character,
Number of decimals, and
Delimiter settings to
Conversion variable
Variable number of characters
setting for Non-verified
reception
Version 2.20W
or later
Acquisition of protocol setting
data error information
Function version B
or later, first 5 digits
of the serial No. are
11062 or greater
Setting execution log options
to buffer memories
Function version B
or later, first 5 digits
of the serial No. are
10122 or greater
Monitor/Test
available
Version 2.18U
or later
Pre-defined
protocol
communication
System registration of the
execution log options to the
flash ROM
Function version B
or later, first 5 digits
of the serial No. are
11062 or greater
Version 8.78G
or later
System
registration into
the flash ROM
can be
performed.
Version 2.20W
or later
Version 1.24A
or later
: Usable (no restrictions depending on the version) : Not usable