3 - 35 3 - 35
MELSEC-Q
3 SPECIFICATIONS
Address
Decimal (Hex)
Applicable
protocol
CH1 CH2
Application Name
Initial
value
MC Non Bi Pd
Registration
Reference
section
8281 to
8361
(2059H to
20A9H)
8537 to
8617
(2159H to
21A9H)
For designation
of programmable
controller CPU
monitoring
function
Block
monitoring
devices No. 2
to 10
The structure of each area is the same as the first block monitoring device
area
See *1 for the details of each area.
Allowed
User's Manual
(Application)
8362 to
8421
(20AAH to
20E5H)
8618 to
8677
(21AAH to
21E5H)
Use prohibited System area
—
8422
(20E6
H)
8678
(21E6H)
Transmission pointer designation (for condition
agreement transmission and non-procedure data
transmission)
0: No designation
1 to 100: Output head point (send from nth)
Send the user frames designated in the following
transmission frame No. designation areas from
the designated pointer position.
(address: CH1 side = BA
H to 11DH, CH2 side =
15A
H to 1BDH)
Output count designation (for condition agreement
transmission and non-procedure data transmission)
8423
(20E7H)
8679
(21E7H)
0: No designation
1 to 100: Output count (designate the number of
frame transmissions)
—
R
Data No. for connection designation (for condition
agreement transmission and notification)
8424
(20E8H)
8680
(21E8H)
For designation
of programmable
controller CPU
monitoring
function
Programmable
controller CPU
abnormal
monitoring
designation
0: No designation
0BB8
H to 0BD5H, 8001H to 801FH: Data No. for
connection
0
R
— Allowed
User's Manual
(Application)
8425 to
8447
(20E9H to
20FFH)
8681 to
8703
(21E9H to
21FFH)
Use prohibited System area
—
8448 (2100H)
Use Prohibited System area
—
8449 (2101H)
Data No. for callback designation 1
0BB8
H to 0BD5H, 8001H to 801FH: Data number for callback.
8450 (2102H)
Data No. for callback designation 2
8451 (2103H)
Data No. for callback designation 3
8452 (2104H)
Data No. for callback designation 4
8453 (2105H)
Data No. for callback designation 5
8454 (2106H)
Data No. for callback designation 6
8455 (2107H)
Data No. for callback designation 7
8456 (2108H)
Data No. for callback designation 8
8457 (2109H)
Data No. for callback designation 9
8458 (210AH)
For callback
function
Data No. for callback designation 10
0
R
W
—
Allowed
Section 9.4.4
User’s Manual
(Application)
8704 to
8707
(2200H to
2203H)
8960 to
8963
(2300H to
2303H)
Use prohibited System area
—
8708
(2204H)
8964
(2304H)
Programmable controller CPU monitoring function operation status
0: Not executed (waiting for registration of programmable
controller CPU monitoring)
1: Wait for programmable controller CPU monitoring time
(waiting to access programmable controller CPU)
2: Accessing programmable controller CPU
3: Sending monitoring results
Programmable controller CPU monitoring function execution result
(current)
8709
(2205H)
8965
(2305H)
0: Normal completion
1 or more: Abnormal completion (error code)
Programmable controller CPU monitoring function number of
transmission
8710
(2206H)
8966
(2306H)
Programmable
controller CPU
monitoring
function
0: Not executed
1 or more: Number of transmissions
0 R — Not allowed
User's Manual
(Application)