Operating Instructions MG3 Digital
Commissioning
76609409EN-BA-MG3D-V1_6.docx 16/82 2010-08-02
3.1.2.3 Connector X38 (I/O Outputs)
Pin Name Chann.
Function
3
4
Sinking Path min.
Sinking Path
max.
1
1
Depending on setup default; becomes active if the
currently measured sinking path min./max. is
exceeded or remains under
5
6
Sinking Path min.
Sinking Path
max.
2
2
see above
7 Prewarn Dist. S3
1
8 Prewarn Dist. S6
2
9 Sinking 2 Accept
2
2 Output enabled if sinking path 2 is ACCEPT
10 Sinking 1 Accept
1
1 Output enabled if sinking path 1 is ACCEPT
11 Pressure/Force
reject
1
12 Pressure/Force
accept
1
13 Pressure/Force
reject
2
14 Pressure/Force
accept
2
17
31
Path Abort
current High
Path Abort
current Low
2
2
Output active on High; is enabled if cutoff value is
exceeded.
Output active on Low; is enabled if cutoff value is
exceeded.
18,
21
Plus terminal (+)
Common plus terminal (+) for PIN:
14, 13, 11, 12, 10, 9, 8, 7, 6, 5, 4, 3, 30, 29, 28, 27,
26, 25, 24, 23
19 Common (+) 1
1 Common plus terminal 10 – 30 V for PIN 16 and 20.
20
16
Path Abort
Current High
Path Abort
Current Low
1
1
Output active on High; is enabled if cutoff value is
exceeded.
Output active on Low; is enabled if cutoff value is
exceeded.
25 Parts Detection
Low active
1 if limit values are not reached or exceeded, then this
output is switched off (pressure switch control unit),
26 Parts Detection
Low active 2
2 if limit values are not reached or exceeded, then this
output is switched off (pressure switch control unit),
27
28
Path Parts
Detection min.
Path Parts
Detection max.
1
1
Depending on setup default; becomes active if the
currently measured parts control path min./max. is
exceeded or remains under.
29
30
Path Parts
Detection min.
Path Parts
Detection max.
2
2
Depending on setup default; becomes active if the
currently measured parts detection path min./max.
is exceeded or remains under.
34 Common (+)
2 Common plus terminal 10 – 30 V for PIN 17 and 34.