EasyManua.ls Logo

Money Controls MechTool SR5 User Manual

Default Icon
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SR5 MechTool
TM
Manual TSP012.doc Issue 2.1 – June 2004
This document is the copyright of Money Controls Ltd and may not be reproduced in part or in total by any means,
electronic or otherwise, without the written permission of Money Controls Ltd. Money Controls Ltd does not accept
liability for any errors or omissions contained within this document. Money Controls Ltd shall not incur any
penalties arising out of the adherence to, interpretation of, or reliance on, this standard. Money Controls Ltd will
provide full support for this product when used as described within this document. Use in applications not covered
or outside the scope of this document may not be supported. Money Controls Ltd. reserves the right to amend,
improve or change the product referred to within this document or the document itself at any time.
©Money Controls 2004. All rights reserved.
Question and Answer IconNeed help?

Do you have a question about the Money Controls MechTool SR5 and is the answer not in the manual?

Money Controls MechTool SR5 Specifications

General IconGeneral
TypeBank Note Validator
Stacker Capacity200 notes
Operating Temperature0°C to +60°C
Storage Temperature-20 to 70 °C
Communication InterfaceSerial (RS232), Parallel, MDB, USB

Summary

Diary of Changes

Introduction

Diagnostics

Overview of self checks/tests available for the SR5.

Inhibit / Accept line and Inductive Noise Test

Checks inhibit/accept lines and detects environmental noise levels.

Solenoid and Inductive Sensor Flash Test

Tests solenoid operation and the status of sensor coils.

Opto Test

Checks the status of opto devices and the dual coin entry.

MechTool™

Describes the MechTool™ feature for on-site programming.

MechTool™ Controls

Diagnostics

Inhibit / Accept line and Inductive Noise Test

Tests inhibit/accept lines and assesses sensor noise levels.

Solenoid and Inductive Sensor Flash Test

Tests solenoid drives and inductive sensor coil functionality.

Opto Test

Explains how to test the performance of opto electronic devices.

Exit Diagnostics

Instructions on how to properly exit diagnostic modes.

Token Selection

Token Disable - Position 0

Disables token acceptance by setting rotary switch to position 0.

Token Selection - Position 1 to C

Selects pre-programmed tokens using rotary switch positions 1 to C.

Mode Control - Position D

Routing Control - Position E

Teach and Run™ Token 12 - Position F

Teach and Run™ Coins

Details the procedure for teaching all 16 available coin positions.

MechTool™ Mode

MechTool™ ENTRY

Step-by-step guide to entering the MechTool™ programming mode.

MechTool™ EXIT

Instructions for safely exiting MechTool™ mode.

Window Tuning

Window adjustment table

Table correlating EEPROM flags with window tuning operations.