9. MechTool
TM
Mode
The LED is used to show at which stage the user is when the SR5 is in MechTool
TM
mode. The
colours are used as follows:
¾ LED green : SR5 normal operation - OK
¾ LED flashing yellow : MechTool
TM
mode selected – first level
¾ LED flashing yellow-green : second level of MechTool
TM
mode
¾ LED flashing yellow-red : third level of MechTool
TM
mode
¾ LED flashing green : fourth level of MechTool
TM
mode
9.1 MechTool
TM
ENTRY
This mode is selected by setting the rotary switch to position 0 and then pressing the
program button for minimum of 2 seconds. The LED changes colour from Green to Red and
then to flashing Yellow.
If the LED stays Red and then changes back to Green when released, or the LED remains
Green, then MechTool
TM
has not been enabled and the following functions are not available.
The following functions can be selected; flow charts are also attached.
The numbers (below) represent the rotary switch positions.
0. MechTool
TM
mode enter/exit.
1. Teach coin mode (after entering this mode, select the window number).
2. Window tweaks mode (after entering this mode, select the window number then select
the tweak value).
3. Test credit.
4. Test alarm.
5. Test gate.
6. Flag change mode (after entering this mode the following flags can be changed):
i. Teach off.
ii. Teach on.
iii. Alarm off.
iv. Alarm on.
v. Diagnostic off.
vi. Diagnostic on.
vii. Individual window tweaks disabled.
viii. Individual window tweaks enabled.
ix. Secure tuning disabled.
x. Secure tuning enabled.
7. Reset all individual coin tweaks to zero.
8. Erase all windows (the program button has to be pressed twice within 1 second to erase
windows).
9.2 MechTool
TM
EXIT
To exit the MechTool
TM
mode, set the rotary switch to position 0 and then press the program
button for minimum of 2 seconds, the LED changes colour from flashing Yellow to flashing
Green-Yellow.
Releasing the program button changes the LED colour to Green.