SR5 MechTool
TM
Manual TSP012.doc Issue 2.1 – June 2004
©Money Controls 2004. All rights reserved.
Page 11 of 24
1
2
ON
7. Routing Control - Position E
The SR5 allows you to change between EEPROM mode, (factory programmed sorting
configurations) and routing plug mode.
To set the routing, ensure that the SR5 is powered up through the main parallel connector.
To use:
¾ Make a note of the rotary switch position and the bank select switch positions.
¾ Turn the rotary switch to position E.
¾ Set bank select switch 1 to the desired routing mode.
¾ Press and hold the program button, the LED will change to RED.
¾ Release the program button.
¾ The LED will change back to GREEN.
¾ Set the rotary switch and bank select switches to their original positions.
¾ Press and hold the program button, the LED will change to RED.
¾ Release the program button.
¾ The LED will change back to GREEN.
Note: If the LED stays Green then Routing Control “E” is not available.
NEVER leave the validator with the rotary switch in positions D, E or F.
Not UsedRouting Plug Mode
EEPROM Mode
Not Used