Flow Chart 4: Test Alarm Outputs
RS = Rotary Switch Position
LED Colour
RS = 0
MechTool
TM
Mode - Entry
Set RS to position 0 Green
Press and hold program button for a
minimum of 2 seconds.
Red
Release the program button when the
LED flashes Yellow.
Flashing Yellow
RS = 4
Test Alarm Outputs
Set RS to position 4 Flashing Yellow
Press and release the program button. Yellow-Green
Once the program button is released
the alarm code
#
will be output ONCE.
The program button has to be pressed
again to repeat.
RS = 0
MechTool
TM
Mode - Exit
Set RS to position 0 Flashing Yellow
Press and hold program button for a
minimum of 2 seconds.
Yellow-Green
Release the program button when the
LED = Yellow-Green.
Green
#