29
Rev. 1.1
0004102014
400-820-9661
SS03/05/10-S/Q/C Hardware Manual
3.3 Analog Inputs
SS series drive has two analog signal inputs which can accept signal range of 0-5 Volts,0-10 volts
9RU9ROWV7KHGULYHFDQEHFRQ¿JXUHGWRRSHUDWHDWYHORFLW\PRGHRUSRVLWLRQPRGHWKDWLV
proportional to the analog input.
8VHWKH6WHS6HUYR4XLFN7XQHUWRFRQ¿JXUHWKHLQSXWUDQJHRIIVHWGHDGEDQGDQGQRLV\¿OWHU
frequency.
SS series provides a +5V/100mA limit power supply that can be used to power external devices
such as potentiometer. It is not the most accurate supply for reference,for more precise readings
use an external supply that can provide the desired accuracy.
+5v OUT
AIN
GND
1 - 10k
pot
SS-S/Q/C
Connecting a Potentiometer to An Analog Input