31
Rev. 1.1
0004102014
400-820-9661
SS03/05/10-S/Q/C Hardware Manual
5.2 Alarm Error Code
The faults of drive are shown in
bold italics
. Motor will disable(Servo Off) when faults occur.
Position Limit
CCW Limit
CW Limit
Over Temperature
Over Voltage
Under Voltage
Internal Voltage
Over Current
Current Foldback
Open Winding
Bad Encoder
Flash Memory Error
NV Memory Error
Communication Error
Move while Disabled
Regen Failed
Q Program Running
LED2 is used to indicate bus address and communication baud rate.
Because the power-up serial communication baud rate is always 9600(BR=1). So after power
XS/('ÀDVKHV³´WRLQGLFDWHWKHVHULDOFRPPXQLFDWLRQEDXGUDWHIRUVHFRQGV7KHQLWZLOO
ÀDVKHVWKHUHDORSHUDWLRQEDXGUDWH%5
BR Baud Rate(bps)
1 9600
2 19200
3 38400
4 57600
5 115200
About 6 seconds later,LED2 turns to solid to indicate the bus address for RS-485 or CANopen
drive. SS-P/R drive always display “0”.