8
3.6. Features
3.6.1. Selecting the display language
Menu
Possible settings
Default setting
Parameters
Languages XX
Français
English
Deutsch
Español
Italiano
Nederlander
Portugués
English
3.6.2. Setting the date and time
Menu
Possible settings
Default setting
Parameters
Date XX/XX/XX
Month / Day / Year
01/01/01
Parameters
Time XX:XX
Hour / Minute
random
3.6.3. Sensor settings
Menu
Sensor
Setting
Possible settings
Default setting
Parameters
Sensors
Cover/Ext cmd
Mode
Cover
OFF
Ext cmd
Cover
Type
NO
NC
NO
Flow
Mode
Flow
OFF
ON
Type
NO
NC
NO
Salt
-
ON
OFF
ON
Temperature
Ext cmd : external command.
ON : sensor activated.
OFF : sensor disabled.
NO : switch normally open.
NC : switch normally closed.
Sensor activated
Configuration
Specific
display
Production
Cover
Open cover
-
Maintained
Closed cover
Cover
Divided by 5
External command
Command activated
-
Maintained
Command not activated
Ext
Stopped
Flow
Sufficient flow
-
Maintained
Zero flow
Alarm
Flow
Stopped
Salt
Salt level less than 2500 ppm
(or 1200 ppm if Low Salt equipment)
Alarm
Low Salt
Stopped
Salt level equal to or greater than 2500 ppm (or
1200 ppm if Low Salt equipment)
-
Maintained
Temperature
Water temperature below 59°F
Low Temp
Mode
Stopped
Water temperature equal to or higher than 59°F
-
Maintained

Table of Contents