3.6.10. Activation/deactivation of the pH measurement (option)
Menu
Possibles settings
Default setting
pH regulation
Mode XXX
ON
OFF
ON
3.6.11. Setting the salinity
Menu
Possible settings
Default setting
Electrolysis
Salinity XX
NS: 3200 ppm
LS: 1500 ppm
NS
3.6.12. Boost mode
Boost mode :
- sets the production setpoint up to 125 %, for a fixed period.
- can be manually stopped at any time.
- can be used when chlorine is urgently needed.
I Boost mode cannot replace a conventional shock treatment in cases of water not fit for bathing.
If the Boost mode is restarted manually while it is already running, the Boost mode resets for the duration displayed.
Boost mode cannot be switched on if an alarm has been triggered. After having resolved and dismissed this alarm,
wait a few moments in order to be able to activate the Boost mode.
When the Boost mode ends or is manually stopped, production continues according to the initial setpoint.
Boost mode continues after powering off the electronics unit.
Operation with a cover sensor :
Boost mode cannot be switched on with the cover shut.
If the cover is closed with Boost mode switched on, Boost mode automatically stops.
Menu
Possible
settings
Default
setting
Switching on
Operation indicator
(specific display variants)
Switching off
Electrolysis
Boost
12 h
24 h
24 h
Automatic as soon as the
duration setting is confirmed.
Bo 12 h or Bo 24 h
Press on .
Boost 12 h or Boost 24 h
3.6.13. Calibrating the probes : important advance information
The original pH probe is already calibrated. It is therefore not necessary to carry out calibration of the pH probe
when putting the equipment into service for the first time.
I However, it is imperative to carry out a calibration of the pH probe at the beginning of each season when
returning to service, and after each probe replacement.
3.6.14. Calibrating the pH probe
1) Open the pH 7 and pH 10 calibration solutions (use only single-use calibration solutions).
2) Turn off the filtration (and therefore the electronics unit).
3) If the probe is already installed :