3.6.4. Calibration of the water temperature measurement
→ If the temperature sensor is disabled, the menu below does not appear.
From – 9°F to + 9°F compared to the measurement
displayed, in increments of 1.
3.6.5. Calibration of the salt rate measurement
→ If the salt sensor is disabled, the menu below does not appear.
From 1500 to 8000 ppm, in increments of 100
3.6.6. Calibration of the pH measurement (option)
From 6.5 to 7.5, in increments of 0.1.
3.6.7. Setting the inversion frequency of the current supplying the cell
I Current inversion aims to prevent scale deposits on the cell. Current inversion must be set following the table
below in order to ensure that the cell continues to operate correctly in the long term.
Electrolysis
Inversion XX h
From 2 to 24 h, in increments of 1.
3.6.8. Selecting the chlorinator operating mode
Continual production, following the
production setpoint.
Deactivation of the chlorinator cell.
→ The choice of operating mode can be seen on the initial display (« PROD » as a %).
3.6.9. Setting the production setpoint
Chlorinator
operating mode
Directly select a value using
the buttons (no
confirmation required).
• From 10 to 100 %, in
increments of 1.
• OFF (depending on the
operating mode of the
chlorinator).