Please note that the following maintenance intervals apply for normal operating conditions only. Intervals are
hours of operations based on 8 hours per day, 5 days per week. If your operating conditions are difcult, adjust
the specied intervals accordingly.
start up
8 hrs
40 hrs
300 hrs
X = 1 SHOT OF GREASE
1) Discharge X X
2) Drum
1)
X X
3) Feed wheel/hub
2)
(see next page)
4) Infeed X X
5) Battery Box XX
6) Radiator fan stub shaft bearings X X
7) Tracks X
1) Only grease zerk above aluminum grease seals need to be greased.
2) Change oil after rst 100 hours of operation, then annually or every 1000 hours with 90 weight gear oil with EP additives.
3) See routine maintenance schedule
4) Side load adaptors get 2 shots of grease
ROUTINE LUBRICATION SCHEDULE