03/15
•
45
Please note that the following maintenance intervals apply for normal operating conditions only. Intervals are
hours of operations based on 8 hours per day, 5 days per week. If your operating conditions are difcult, adjust
the specied intervals accordingly.
start up
8 hrs
40 hrs
300 hrs
X = 1 SHOT OF GREASE
1) Discharge X X
2) Drum
1)
X X
3) Feed wheel/hub
2)
(see next page)
4) Infeed X X
5) Battery Box XX
6) Radiator fan stub shaft bearings X X
7) Tracks X
1) Only grease zerk above aluminum grease seals need to be greased.
2) Change oil after rst 100 hours of operation, then annually or every 1000 hours with 90 weight gear oil with EP additives.
3) See routine maintenance schedule
4) Side load adaptors get 2 shots of grease
ROUTINE LUBRICATION SCHEDULE