NOTE: Its the customer's responsibility to follow all steps of air lter maintenance every 200 hours or every engine oil
change.
Low pre-cleaner efciency will cause short element life. Low pre-cleaning efciency can be caused by:
Leaking dust cup to air cleaner body joint; cup must seal 360° around the air cleaner
A damaged or missing vaccuator valve
Plugging or buildup in the vanes of the pre-cleaner
Damage to the pre-cleaning section of the air cleaner
THE PROBLEM OF AIRBORNE CONTAMINANTS ENTERING THE ENGINE
Check to make sure the element has not been damaged in handling. Examine for dents and holes
Check to make sure all gaskets are sealing. Examine for dust trails which indicate leaks. Check to be certain wing nut is
tight
Examine the clean air transfer tubing for cracks, loose clamps or loose ange joints
Check ether ttings (if used) to be certain no contaminants are entering the engine through these connections
Check the service indicator for damage, working lockup function and correct calibration per engine manufacturer's
recommendation
AIR FILTER MAINTENANCE