No. Test Name Test Setup Terminal Set-
up
Test Condi-
tions
Limits
Network Code 2392
Base Color 1
Location Area 224
Min Rx Level -110 dBm
Max Tx Level 40 dBm (10
W)
Access
Parameter
-33 dBm
Mobile Power 40 dBm (10
W)
Burst Type Normal
2. Base Station
Registration
RF Gen Level 462.725 MHz -90 dBm
3. Receiver
RSSI
RF Gen Level Cells Info
RSSI
TRACE
-90 dBm
4. Transmitter
Tests
RF Gen Level Range 1
Test Group 1
-90 dBm
Burst Power 35–40 dBm
Timing Error <= 0.25 Sym-
bols
Frequency
Error
-/+ 100 Hz
Vector Error Max 10%
RMS,
Max 30%
Peak,
Max 5% Re-
sidual
5. Call Process-
ing Talk Back
1 kHz Test
Signal
Group Mode
Range 1
Test Group 1
-90 dBm
6. Call Process-
ing Call to Mo-
bile
Private Mode
Private Call
Private Mode
RF Gen Level
Burst Power
-90 dBm 35–40 dBm
Timing Error <= 0.25 Sym-
bols
Frequency Er-
ror
-/+ 100 Hz
MN009999A01-AA