AP-7131 Access Point Product Reference Guide8-232
AP7131>admin(system.ntp)> set
Description:
Sets NTP parameters for access point clock synchronization.
Syntax:
Example:
admin(system.ntp)>set mode enable
admin(system.ntp)>set server 1 203.21.37.18
admin(system.ntp)>set port 1 123
admin(system.ntp)>set intrvl 15
admin(system.ntp)>set zone 1
For information on configuring NTP using the applet (GUI), see Configuring Network Time Protocol (NTP) on page 4-41.
set mode <ntp-mode> Enables or disables NTP.
server <idx> <ip> Sets the NTP sever IP address.
port <idx> <port> Defines the port number.
intrvl <period> Defines the clock synchronization interval used between the access point and
the NTP server in minutes (15 - 65535).
time <time> Sets the current system time. [yyyy] - year, [mm] - month, [dd] - day of the
month, [hh] - hour of the day, [mm] - minute, [ss] second, [zone -idx] Index of the
zone.
zone <zone> Defines the time zone (by index) for the target country.