TEST SETUP & TESTING for 380–430 MHz and 410–470 MHz 5.1 - 7
CIRCUIT MODE DATA SERVICE: SUPPORTED
(RESERVED): NOT AVAILABLE
SNDCP SERVICE: NOT AVAILABLE
AIR INTERFACE ENCRYPTION: NOT AVAILABLE
ADVANCED LINK: NOT SUPPORTED
Note: The displayed values are factory defaults and should not be changed.
21. Press the “Return” soft key.
22. Press the “Neighbr Cell” soft key.
23. Verify that the following values are displayed:
NEIGHBOUR CELL BROADCAST: NOT REQUIRED
BROADCAST INTERVAL: 10s
NEIGHBOUR CELL CHANNEL: 0000
NEIGHBOUR CELL LOCATION AREA: 00001
NEIGHBOUR CELL IDENTIFIER: 01
SLOW RE-SELECT THRESHOLD: 10dB
SLOW RE-SELECT HYSTERESIS: 10dB
FAST RE-SELECT THRESHOLD: 10dB
FAST RE-SELECT HYSTERESIS: 10dB
Note: The displayed values are factory defaults and should not be changed.
24. Press the “Return” soft key.
25. Verify that “Trunking Type” is set to “Message”.
26. Press the “Call Type” soft key to enter the “Call Type” screen.
27. Press the “Private Call” soft key.
28. Press the “Simplex Duplex” soft key and “Simplex Call” soft key.
29. Press the “Signal Type” soft key and “Direct set-up” soft key.
30. Press the “Priority” soft key. Thereafter, enter “00” and press the “Priority” soft key.
31. Leave “Calling Party SSI” setting to default value.
32. Press the “Return” soft key.
33. This completes the System Setup configuration.