Advanced Data Formatting 12 - 5
Note also that using standard data editing functions also creates ADF rules. Scan options are entered as ADF
rules, and the previous hierarchy also applies to them. For the decoder, this applies to prefix/suffix programming in
the parameter Scan Data Transmission Format on page 5-15.
These rules reside in the same “rule list” as ADF Rules, so the order of their creation is also important.
Default Rules
Every unit has a default rule to send all scan data. Units with custom software may have one or more default rules
burned in. The rules hierarchy checks user programmable rules first, then the default rules. To disable default rules
enter the following general rule in the user programmable buffer:
When receiving scan data, send all data.
Since this rule always applies, ADF never enters the default rules.